USAfixTM - Repair Guide (RG) - Master Email RG
- Test microswitch for solenoid valve
 Level of Difficulty - HIGH  Estimated Completion Time - 15 minutes
TASKI - FG 2C

Tools Required
Tool 
Screwdriver-phillips
Volt meter (True RMS capable)

Parts Required


Step Procedure & Parts & Tools
1 LAY THE MACHINE DOWN SO THE FRONT COVER IS FACING UP. REST THE MACHINE ON BOARDS SO THAT THE FILTER ON THE BACK DOESNT GET BROKEN.

2 REMOVE THE 4 SCREWS AND LIFT UP ON THE FRONT COVER TO REMOVE IT.
Screwdriver-phillips

3 LOCATE THE TERMINAL BLOCKS. INSERT THE LEADS INTO THE TERMINAL BLOCK AS SHOWN.(ONE LEAD IN THE TOP RIGHT CORNER AND THE OTHER LEAD IN THE TOP LEFT CORNER, EITHER LEAD CAN GO IN EITHER SPOT). TURN THE MACHINE ON AND SET THE VOLT METER TO TEST CONTINUITY AND LISTEN FOR IT TO BEEP. IF THE VOLT METER BEEPS, THE MICROSWITCH IS GOOD.
Volt meter (True RMS capable)

4 IF MICROSWITCH IS OKAY, REVERSE STEPS 1 AND 2 TO REASSEMBLE THE MACHINE.